Irrigation Hydraulic
I.T.G. Innovative Technologies Group Ltd is the exclusive distributor of Raphael Valves Industries Ltd products on the territory of the Republic of Azerbaijan and Georgia.
Raphael Valves Industries is a leader in Automatic, Hydraulic Water Control Valves for the Irrigation Market including: drip irrigation and greenhouses.
Raphael is constantly striving to introduce new and innovative products and materials for water control systems such as: Cast Iron, Ductile Iron and reinforced Nylon.
RAF a new concept of diaphragm hydraulic control valveconsisiting of three basic parts: body, cover and diaphragm.
The "no-spring" diaphragm valve ensures even distribution of pressure on the sealing area, prevents diaphragm deformation and provides longer service life. The valve contains minimum number of moving parts and requires practically no maintenance.
The patented rib-style diaphragm has several advantages. Valves opening and closing is gradual and eliminates risk of water hammer, vibration and noise. It provides accurate and perfect pressure regulation at low flow-rates. Full valve opening is obtained at a very low pressure. One diaphragm controls the whole pressure range.
Diameter: DN25 - DN350
Standard: DIN/ANSI/BS
Electric Control Valve 3-W Plastic SolenoidRAF/RAF-P 31 & 33
Pressure Rating PN-10
Nominal Diameter 1" - 6D"
The RAF/RAF-P 31 electric valve is a Normally Closed (N.C.) line pressure hydraulically actuated. The 3-W solenoid valve changes positions:
The RAF/RAF-P 31 (N.C.) opens when 3-W plastic solenoid valve is energized.
The RAF/RAF-P 31 (N.C.) shuts when 3-W plastic solenoid valve is de-energized.
The RAF/RAF-P 33 electric valve is a Normally Open (N.O.) line pressure hydraulically actuated. The 3-W solenoid valve changes positions:
The RAF/RAF-P 31 (N.O.) opens when 3-W plastic solenoid valve is de-energized.
The RAF/RAF-P 31 (N.O.) shuts off when 3-W plastic solenoid valve is energized.
The 3-W electric solenoid valve configuration together with Raphael's patented diaphragm enables smooth opening and surge free shut off.
Typical Applications
Use RAF/RAF-P 31 & 33:
* for water supply systems with medium pressure rating
* for remote operation of hydraulic valve by an electric command
* for irrigation water distributioin and field control
Hydraulic Remote Control Valve 3-W Galit SolenoidRAF/RAF-P OG3
Pressure Rating PN-10
Nominal Diameter 1" - 6D"
The RAF/RAF-P OG3 is an hydraulic valve operated by line pressure. The valve is a 3-W on/off control valve thta can be commanded from a remote location, by an hydraulic control relay - Galit.
The OG3 can be configured to perform as a Normally Open (N.O.) or as a Normally Closed (N.C.) valve. The valve is fully open when the control chamber is disconnected from line pressure and vented into the atmosphere. The 3-W Galit configuration together with Raphael's patented diaphragm enables smooth and precise downstream pressure control.
Typical Applications
Use OG3:
* for water supply systems with medium pressure rating
* in locations with lightening hazard that damages electric control valves with unprotected solenoid installations.
Pressure Reducing Control Valve 3-W Plastic PilotRAF/RAF-P 63
Pressure Rating PN-10
Nominal Diameter
Inline RAF 1" - 6"
RAF-D 3" - 6"
Angle RAF 2"- 4"
RAF-D 3" - 6"
The RAF/RAF-P 63 pressure reducing valve is a line pressure hydraulically actuated, 3-W plastic pilot. The 63 maintains a constant downstream pressure, as set on the 3-W plastic pilot, regardless of flow changes.
The 3-W plastic pilot configuration together with Raphael's patented diaphragm enables smootha dn precise downstream pressure control.
Typical Applications
Use 63:
* for irrigation
* for water treatment circulation
* for filtration network
Pressure Reducing Control Valve 3-W Electric Plastic PilotRAF/RAF-P 63-31
Pressure Rating PN-10
Nominal Diameter 1" - 6D"
The RAF/RAF-P 63-31 is a Normally Closed (N.C.) pressure reducing valve.
The 63-31 is an electric on/off valve, controlled by a 3-W plastic solenoid valve. When the solenoid is energized the valve opens and performs as a pressure reducing valve, maintaining the preset pressure constant regardless of flow-rate or upstream pressure fluctuations.
The 3-W plastic pilot has a spring loaded membrane, a downstream sensitive and can be preset to a desirable downstream pressure.
The 3-W plastic pilot configuration together with Raphael's patented diaphragm enables smootha dn precise downstream pressure control.
Typical Applications
Use 63-31:
* for irrigation, water distribution and flow control
When downstream pressure should be reduced, the valve is commanded to open
RAF - Hydrauic Diaphragm Valve
RAF a new concept of diaphragm hydraulic control valveconsisiting of three basic parts: body, cover and diaphragm.
The "no-spring" diaphragm valve ensures even distribution of pressure on the sealing area, prevents diaphragm deformation and provides longer service life. The valve contains minimum number of moving parts and requires practically no maintenance.
The patented rib-style diaphragm has several advantages. Valves opening and closing is gradual and eliminates risk of water hammer, vibration and noise. It provides accurate and perfect pressure regulation at low flow-rates. Full valve opening is obtained at a very low pressure. One diaphragm controls the whole pressure range.
Diameter: DN25 - DN350
Standard: DIN/ANSI/BS
Electric Control Valve, 3-W Metal SolenoidRAF/RAF-P 31/33
Pressure Rating PN-16
Nominal Diameter 1" - 14"
The RAF/RAF-P 31 electric is a Normally Closed (N.C.) line pressure hydraulically actuated valve.
The RAF/RAF-P 33 electric is a Normally Open (N.O.) line pressure hydraulically actuated valve.
The 3-Way electric solenoid valve changes positions:
The 31 (N.C.) opens when 3-W solenoid valve is energized.
The 31 (N.O.) shuts off when 3-W solenoid valve is de-energized.
The 33 (N.O.) opens when 3-W solenoid valve is de-energized.
The 33 (N.C.) shuts off when 3-W solenoid valve is energized.
The 3-Way electric solenoid valve configuration together with Raphael's patented diaphragm enables smooth opening and surge free shut-off.
Typical Applications
Use 31/33:
* for water suuply systems with medium pressure rating
* for remote operation of hydraulic valve by an electric command
* for irrigation water distribution and field control
Float Level Control Valve, 2-W Float Pilot RAF/RAF-P 10
Pressure Rating PN-16
Nominal Diameter 1" - 14"
The RAF/RAF-P10 stays open as long as the water level in the reservoir is below the maximum preset level. As the water level rises and filts the float, the valve gradually closes.
The 10 float level control valve is activated by line pressure in any situation that maximum water level should be maintained.
When the water level is low, the control chamber of the valve is drained through the vent, the valve opens and the reservoir is being filled.
Typical Applications
Use 10:
* to fit in remote sites
* to maintain a miximum preset water level in a reservoir or water tank in a simple and an enocomic manner.
* can be located above the water level
Due to its simple design, it is virtually maitenance free.
There is no need for energy other than line pressure.
Bi-Level Control Valve, 3-W Float Pilot RAF/RAF-P 13
Pressure Rating PN-16
Nominal Diameter 1" - 14"
The RAF/RAF-P 13 is activated by line pressure and controls by a float pilot.
The valve will open at a low preset water level and will close at a high preset water level. Therefore, there is no need for energy other than line pressure.
The RAF/RAF-P 13 allows filling and draining of a reservoir or a water tank in a level range that can be easily changed.
The RAF/RAF-P 13 stays in its last position (fully open or fully close) as long as the water level is in between minimum and maximum preset levels.
Typical Applications
Use 13:
* to control filling of reservoirs and water tanks, in any situation that water level is controlled
* is best fit where on/off non-modulating valve operation is essential
Due to its simple design, it is virtually maitenance free.
Electric Float Control Valve, 3-W Metal Solenoid RAF/RAF-P 1031
Pressure Rating PN-16
Nominal Diameter 1" - 14"
The RAF/RAF-P 1031is a Normally Closed (N.C.) electric float control valve, activated by line pressure.
When the level drops below the float, the electric circuit is switched on and opens the valve through a solenoid valve. As the rising water reaches the maximum level, the solenoid is de-energized and the RAF/RAF-P 1013 closes.
Typical Applications
Use 1031:
* for water level control
The valve is best for remote or local control of reservoirs and water tranks level control when electricity is available.
Due to its simple design, it is virtually maitenance free.
METAL FREE
RAF-P the art of plastic with the efficiency of metal
RAPHAEL Valves Industries Ltd., the first Israeli manufacturer of quality Control Valves, is pleased to announce the launch of the new Plastic Hydraulic Control Valve Series, RAF P, which provides excellent performance in fluid control.
RAF-P clever and simple:
3 parts valve: body, "spring-less" diaphragm and cover
RAF-P Benefits and Features:
Available in 1.5", 2", 2" Super, 2.5", 3", 3" Super, 4" & 5"
Unique non metal wetted parts.
Low head/pressure loss and high flow rate
Electric Control Valve 3-W Plastic SolenoidRAF-P 31 & 33
Pressure Rating PN-10
Nominal Diameter 1.5" - 5"
The RAF-P 31 electric valve is a Normally Closed (N.C.) line pressure hydraulically actuated. The 3-W solenoid valve changes positions:
The RAF-P 31 (N.C.) opens when 3-W plastic solenoid valve is energized.
The RAF-P 31 (N.C.) shuts when 3-W plastic solenoid valve is de-energized.
The RAF-P 33 electric valve is a Normally Open (N.O.) line pressure hydraulically actuated. The 3-W solenoid valve changes positions:
The RAF-P 31 (N.O.) opens when 3-W plastic solenoid valve is de-energized.
The RAF-P 31 (N.O.) shuts off when 3-W plastic solenoid valve is energized.
The 3-W electric solenoid valve configuration together with Raphael's patented diaphragm enables smooth opening and surge free shut off.
Typical Applications
Use RAF-P 31 & 33:
* for remote operation of hydraulic valve by an electric command
* for irrigation water distributioin and field control
Manual Control Valve 3-W cock ValveRAF-P 01
Pressure Rating PN-10
Nominal Diameter 1.5" - 5"
The RAF-P 01 manual valve is a Normally Closed (N.C.) line pressure hydraulically actuated.
The 3-W selecting cock valve changes positions:
The RAF-P 01 opens when 3-W selecting cock valve is turned to position "O".
The RAF-P 01 shuts when 3-W selecting cock valve is turned to position "C".
The 3-W ball valve configuration together with Raphael's patented diaphragm enables smooth opening and surge free shut off.
Typical Applications
Use RAF-P 01
* for local operation of hydraulic valve by a manual command
* for irrigation water distributioin and field control
Hydraulic Remote Control Valve 3-W Hydraulic RelayRAF-P OG
Pressure Rating PN-10
Nominal Diameter 1.5" - 5"
The RAF-P OG is an hydraulic valve operated by line pressure. The valve is a 3-W on/off control valve that can be commanded from a remote location, by an hydraulic control relay - (Hydraulic relay)
The OG can be configured to perform as a Normally Open (N.O.) or as a Normally Closed (N.C.) valve. The valve is fully open when the control chamber is disconnected from line pressure and vented into the atmosphere.
The 3-W Hydraulic relay configuration together with Raphael's patented diaphragm enables smooth and precise downstream pressure control.
Typical Applications
Use OG:
* in situations where the opening and closing control unit is installed in a central location and connected with the field valves by control tubing.
* in locations with lightening hazard that damages electric control valves with unprotected solenoid installations.
Pressure Reducing Control Valve 3-W Plastic PilotRAF-P 63
Pressure Rating PN-10
Nominal Diameter 1.5" - 5"
The RAF-P 63 pressure reducing valve is a line pressure hydraulically actuated, 3-W plastic pilot.
The RAF-P 63 maintains a constant downstream pressure, as set on the 3-W plastic pilot, regardless of flow changes.
The 3-W plastic pilot configuration together with Raphael's patented diaphragm enables smootha dn precise downstream pressure control.
Typical Applications
Use 63:
* for irrigation
* for water treatment circulation
* for filtration network
|
Plastic - PC
3-W Pressure Pilot Control
Valve Diameter 1"- 6D"
Application
The Plastic PC, 3-W pressure pilot, is used in pressure reducing and pressure sustaining/relief applications. Two pilot valves can be combined together on single vale to form bi-functional valve operation.
Combining pressure reducing and pressure sustaining functions is used to prevent excess water flow during pipeline filling.
The pressure regulating model is available in normal pressure or low pressure configurations.
The pilot valve body is made of high quality reinforced plastic.
Calibration may be performed by means of an adjusting screw located on the top of the valve.
Pressure rating: PN-10
Sensitivity: 0.3 bar
Max. temperature: 70C
Weight: 0.322 kg
|
Plastic - FC
3-W Differencial Flow Pilot Control
Valve Diameter 1"- 6D"
Application
The Plastic FC, 3-W differencial flow pilot, is a flow regulating pilot valve. The pilot can be used for flow regulating applications or together with model PC pilot in combined flow and pressure regulating applications. The pilot valve body is made of high quality reinforced plastic.
Calibration may be performed by means of an adjusting screw located on the top of the valve.
Pressure rating: PN-10
Sensitivity: 0.3 - 0.6 bar
Max. temperature: 70C
Regulating accuracy: 8% of flow rate
Weight: 0.3 kg
|
|
Galit
3-W Plastic Solenoid
Valve Diameter 1"- 6D"
Application
The GALIT is equipped with 4 hydraulic connections and a manual operator.
It converts an external hydraulic command that controls the valve. It also enables a manual control of the valve.
The GALIT is suitable for remote opening and closing of hydraulic valves and can be configured as (N.O.) or (N.C.).
Pressure rating: PN-10
Sensitivity: 0.3 bar
Max. temperature: 90C
Weight: 0.64 kg
|
|
Plastic Solenoid
3-W wp-8
Valve Diameter 1"- 6D"
Application
Raphael's plastic solenoid valves are mounted on PN-10 valves.
The Raphael's plastic solenoid valve has an electric coil responding to different currents and includes manual override.
Plastic solenoid valve bases are available with or without flange connection.
Pressure rating: PN-8
Max. pressure: 10 kg/cm2
Max. temperature: 80C
Weight: 0.103 kg
Power source: 110V, 220V (AC) & 9V, 12V, 24V (DC)
|
|
Metal Solenoid
3-W wp-16
Valve Diameter 1"- 6D"
Application
The 3-W metal solenoid (N.C.) or (N.O.) is recommended for heavy duty applications where high performance is required.
The 3-W metal solenoid (N.C.) or (N.O.) can be used for industrial, irrigation control and automation systems.
Pressure rating: PN-16
Max. temperature: 80C
Weight: 0.267 kg
Power source: 110V, 220V (AC) & 9V, 12V, 24V (DC)
|
|
|
P-161
2-W Pressure Reducing Pilot
Valve Diameter 1"- 14"
Application
The P-161, 2-W pilot, operates when hydraulic pressure is applied below the spring loaded membrane which is connected to the pilot's seal trim.
The P-161 is Normally Open (N.O.) pilot. Once pipeline pressure is built downstream of the main valve, it will be conveyed to the pilot's membrane through the sensor port. When the pressure surpasses the set point (pre adjusted thorugh the pilot's adjusting screw) the membrane moves upwards and water passage closes, closing the main valve. When the downstream pressure reduces below the pilot's set point, the membrane moves downwards and opening the water passage.
Pressure rating: PN-16
Regulation ratio: 5.1
Kv rate: 0.25 (l/sec)
Sensitivity: 0.1 bar
Max. temperature: 90C
Ports: 1/4"
Weight: 2.0 kg
|
|
P-162
2-W Pressure Reducing Pilot
Valve Diameter 1"- 14"
Application
The P-162, 2-W pilot, operates when hydraulic pressure is applied below the spring loaded membrane which is connected to the pilot's seal trim.
The P-162 is Normally Open (N.O.) pilot. Once pipeline pressure is built downstream of the main valve, it will be conveyed to the pilot's membrane through the sensor port. When the pressure surpasses the set point (pre adjusted thorugh the pilot's adjusting screw) the membrane moves upwards and water passage closes, closing the main valve. When the downstream pressure reduces below the pilot's set point, the membrane moves downwards and opening the water passage and allowing the main valve to open.
Pressure rating: PN-16
Regulation ratio: 4.1
Kv rate: 0.25 (l/sec)
Sensitivity: 0.1 bar
Max. temperature: 90C
Ports: 1/4"
Weight: 0.75 kg
|
|
P-181
2-W Pressure Sustaining/Relief Pilot
Valve Diameter 1"- 14"
Application
The P-181, 2-W pilot, operates when hydraulic pressure is applied below the spring loaded membrane which is connected to the pilot's seal trim.
The P-181 is Normally Closed (N.C.) pilot. When no pressure is applied below the spring loaded membrane, the pilot commands the main valve to close. When the pressure surpasses the set point, the membrane moves upwards and water passage opens, opening the main valve. When the downstream pressure reduces below the pilot's set point, the membrane moves downwards, closing the water passage.
During the pilot's operation water circulates constantly through the pilot, it provides an immediate response to any changes in pipeline pressure.
Pressure rating: PN-16
Regulation ratio: 5.1
Kv rate: 0.25 (l/sec)
Sensitivity: 0.1 bar
Max. temperature: 90C
Ports: 1/4"
Weight: 2.0 kg
|
P-182
2-W Pressure Sustaining/Relief Pilot
Valve Diameter 1"- 14"
Application
The P-182, 2-W pilot, operates when hydraulic pressure is applied below the spring loaded membrane which is connected to the pilot's seal trim.
The P-182 is Normally Closed (N.C.) pilot. When no pressure is applied below the spring loaded membrane, the pilot commands the main valve to close. When the pressure surpasses the set point, the membrane moves upwards and water passage opens, opening the main valve. When the downstream pressure reduces below the pilot's set point, the membrane moves downwards, closing the water passage.
During the pilot's operation water circulates constantly through the pilot, it provides an immediate response to any changes in pipeline pressure.
Pressure rating: PN-16
Regulation ratio (sustaining): 4.1
Regulation ratio (relief): 7.1
Kv rate: 0.25 (l/sec)
Max. temperature: 90C
Ports: 1/4"
Weight: 0.75 kg
|
|
|
P-683
3-W Pressure Sustaining/Reducing Pilot
Valve Diameter 1"- 14"
Application
The P-683 operates only if pipeline coniditons changes, when hydraulic pressure is applied below the spring loaded membrane, which is connected to the pilot's seal trim, alternating the pilot's water passage.
When the pilot reaches the desired set point, the seal trim locks all water passages, there is no water flow in the pilot and the pilot remains in this position until a change is the downstream pressure.
The P-683 can be used either as a Normally Open (N.O.) or Normally Close (N.C.)
N.O. Configuration
When the pressure head in the pilot's sensor port is lower than the set point, the membrane moves downwards, closing pressure supply to the control chamber and opening a water passage. Once pressure head is built, the membrane moves upwards opening the pressure supply to the control chamber and closing the pilot's vent, allowing the main valve to close.
Pressure rating: PN-16
Regulation ratio: 3.1
Kv rate: 0.25 (l/sec)
Max. temperature: 90C
Ports: 1/4"
Weight: 0.9 kg
|
P-10
2-W Flow Level Pilot
Valve Diameter 1"- 6D"
Application
The P-10 is a flow pilot that is interconnected by a lever arm. When water level reaches its maximum level, the float rises, closing the water passage of the pilot and commands the main valve to close.
When water level drops, the float opens the water passage and main valve will open.
Every change in water level is conveyed to the pilot directly through the lever arm.
The pilot's water passage will open proportionally to the water level.
The P-10 is usually used to command level control valves in small and medium water reservoirs.
There is no need for energy other than line pressure; it offers an economic control solution.
Pressure rating: PN-10
Range: 10 cm
Kv rate: 0.45 (l/sec)
Sensitivity: 0.02 bar
Max. temperature: 90C
Ports: 1/2"
Weight: 1.2 kg
|
|
P-100
2-W Differential Pilot
Valve Diameter 1"- 14"
Application
The P-100 is a Normally Open (N.O.) and a differential pilot. The P-100 operates when hydraulic pressure is applied below and above the spring loaded membrane which is connected to the pilot's seal trim. Upper and lower chambers of the pilot are connected to upstream and downstream sides of a calibrated orifice plate, used as a flow sensor. Differential pressure across the orifice changes with flow, and conveyed to the pilot through its sensing ports. When low pressure difference is presented across the orifice plate, the valve opens. When pressure difference increases, the valve tends to close, maintaining the requested flow.
Pressure rating: PN-16
Regulation Ratio: 3.1
Kv rate: 0.25 (l/sec)
Range: 10 cm
Sensitivity: 0.02 bar
Max. temperature: 90C
Ports: 1/4"
Weight: 2.0 kg
|
|
S.V. Shuttle Valve
General Description
The shuttle valve is a 3-W hydraulic device, used to alternatively forward hydraulic command to the valve's control chamber from two different pressure supply devices. When the higher pressure is conveyed into the central connection from one end, the other end will be shut.
The shuttle valve is availabe in metal and plastic to fit PN-16 and PN-10 control applications.
Applications
The shuttle valve is specifically desinged to operate where two different hydraulic commands are present ina 3-W control system. Either remote operating and/or pilot control will alternatively operate by using the shuttle valve.
|
BM - Needle Valve
General Description
The needle valve is used in control system to enable the pilot control of modulating applications and provide an opening and closing regulated speed. The needle valve is used when valve operating speed and sensitivity are essential for the control system. Raphael's needle valve has a heavy duty stainless steel seat and needle construction, enabling high sensitivity and maintenance free operation.
Application
Use the needle valve in 2-W control systems for modulation purposes. Also use the needle valve in 2-W and 3-W control systems to regulate the valve's opening and closing speed. The needle valve is specially designed for both PN-10 and PN-16 irrigation system. |
|
|
FI - Finger Filter
General Description
The finger filter is a self flushing screen filter installed in the water inlet of the valve's control system.
It is used to prevent impurities from infiltrating into the control system and disturbing its operation by restricting, or even clogging, water passages.
Raphael's finger filter is desinged to be maintenance free, screwed into the valve's body sampling water from the main pipe. The finger filter will provide a safe water source into the control loop.
Application
The finger filter is ideally desinged for operation with RAF hydraulic control valve for irrigation applications as a main filter for the control system, for both PN-10 and PN-16 applications.
Use the FI finger filter in any control system to prevent eventaul malfunction due to impurities, installing it in the water intake to the control loop.
|
SY- 3-way Cock Valve
General Description
The SY 3-W cock valve is a 3 port spherical valve, mounted on the valve's control chamber and used to change water passage between control chamber and 3 other optional ports. The SY is equipped with 4 connections<
1- Common port (unmarked) - always connected to the valve's control chamber.
2- "O"- connects the valve's control chamber to the open air and used to override the control system, manually opening the valve.
3- "C" - connects the valve's control chamber to the pressure supply and used to override the control system, manually closing the valve.
4- "A" - connects the valve's control chamber to the control system and used as the default operating position to be able to use the automatic control function of the application.
Application
Use SY 3-W cock valve with every RAF valve application where override option is necessary, enabling local opening and closing of the valve, regardless of the automatic control function command. The SY is desinged for both PN-10 and PN-16 control systems.
|
|
BK- 2-way Ball Valve
General Description
The BK 2-way ball valve is a spherical valve used as isolating device in the valve's control loop.
The BK is desinged not to interfere in the routine operation of the control system, with minimum head-loss and maximized reliability.
Application
Use the BK 2-way ball valve as an isolation valve when the control system needs to be manipulated.
The BK will eliminate water passage from the main pipe line and enable manipulation and maintenance without the need to shut down the water in the main pipeline.
|